Infection control

Cross-contamination from reusable bronchoscopes

Is contamination of endoscopes really a problem?

It sure is. More nosocomial infection and pseudo-infection outbreaks have been linked to contaminated endoscopes than to any other medical device.1

The results of an investigation conducted by a U.S. Senate committee proves that between 2012 and the spring of 2015, endoscopes caused at least 250 life-threatening infections worldwide, including infections with the superbug carbapenem-resistant enterobacteriaceae.2

Contamination and inadequate cleaning of endoscopes has been recognized as a major patient safety issue by the ECRI - a non-profit US organization focusing on improving patient safety. Therefore, the annual ECRI list of "Top 10 Health Technology Hazards” has included this issue continuously for the past 9 years.3

Would you like more information?


Sign up here

Biofilm risk in reusable endoscopes

Routine cleaning procedures do not remove biofilm reliably from endoscope channels.
Therefore, implementation of infection control through microbiological surveillance of endoscope reprocessing is appropriate to detect early colonization and biofilm formation in the endoscope and to prevent contamination and infection in patients after endoscopic procedures.

 

FDA requires infection control

On March 12, 2015 the U.S. Food and Drug Administration announced new actions to enhance the safety of reusable medical devices and address the possible spread of infectious agents between usages.4, 5, 6

Safety communication on bronchoscopes by FDA

Since then the FDA has issued a new guidance on reprocessing of medical devices, hosted a 2-day seminar discussing the transmission of infection associated with endoscopes, issued warnings to duodenoscope manufacturers for lack of filing MDR reports, as well as issued a safety communication on the infection associated with reprocessed flexible bronchoscopes.6


FDA interventions

March, 2015: 
New guidance on reprocessing of medical device

May, 2015: 
2-day seminar to address problems with contaminated endoscopes

August, 2015: 
Postmarket surveillance studies on endoscopes required

August, 2015:
Warnings to duodenoscope manufacturers

September, 2015: 
Safety communication on bronchoscopes

November, 2016: 
Two patients died due to a contaminated bronchoscope in a US facility7

January, 2017: 
MDR on contaminated bronchoscopes breaks the record with 183 MDRs reported to FDA in 20167

 

Infected bronchoscopes pose a particular challenge

Flexible bronchoscopes are difficult to clean and disinfect due to their long, narrow lumens and delicate materials. The question is whether it is possible to ensure 100% disinfection of each scope. Despite following cleaning instructions persistent device contamination has been seen, and failure to meticulously follow cleaning instructions is likely to lead to contaminated scopes.6, 8

Routine cleaning is not enough

The true incidence of cross-contamination and infection during flexible bronchoscopy is likely under-recognized due to underreporting and inadequate or no surveillance.8, 9

In an overview of infections associated with flexible bronchoscopy from 2013, 50 studies were identified. In 30 out of the 50 studies published the same contaminant was found in the patient as well as in the bronchoscope. A total of 569 contaminated patients and 115 infected patients (20.21%) could be directly related to contaminated bronchoscopes.8

Routine cleaning does not effectively remove biofilm from endoscope channels. Biofilm was present in 13 out of 13 endoscopes despite appropriate cleaning procedures being followed in the channels of 12 out of 13 instruments.10

 

Soil and micro-organisms in suction channels

Electron micrographs of a suction channel that show surface defects.

The biological soil is associated with the defects and is also attached to undamaged areas.

A magnification of one of the defect areas that shows soil and various types of micro-organisms.

Soil and biofilm in air/water channels

Electron micrographs of two different air/water channels with biofilms.

A low-power view showing a confluent layer of soil and biofilm.

A multilayered biofilm consisting of healthy-looking cells surrounded and overlayed with amorphous-looking exopolysaccharides.

The risk of resistant bacteria strains is increasing

Intensivists, hygiene nurses and others involved in infection control have been aware of the risk of contamination and infection of patients under medical care for many years. The arrival of Multi-Drug Resistant Organisms (MDRO) such as CRE or multidrug resistant Pseudomonas aeruginosa constitutes a new challenge when it come to the risks involved for patients, physicians, hospitals and clinics.

Watch the video that demonstrates how bronchoscopes pose a particular risk of patient to patient cross-contamination.

Financial impact of cross-contamination

An independent expert panel, using the Delphi method, revealed a 3,4 % mean risk of cross-contamination from bronchoscopes.11 This is in alignment with findings in another study, where 10 (4%) out of 251 patient-ready bronchoscopes were contaminated despite cleaning.12

As the majority of patients contaminated from bronchoscopes suffer from pneumonia8,13 costs linked to ventilator associated pneumonia ($28.383) are used as the clinical impact in the calculation of costs. Combining the 3,4% risk of cross-contamination with the 21,3% infection risk, the cost associated with cross-contamination can be calculated:

0.034 x 0.213 x 28.383 = $149-203*


*Depending sources, risk of contamination and infections plus cost of VAP.

3,4% risk of a cross-contamination11 times the risk of an infection (calculation based on Kovaleva et al.8) times the cost of a ventilator-associated pneumonia $28.383.11  

In a recent Pseudomonas outbreak, the health-care costs directly related to the diagnosis, treatment, and hospitalization of the six affected patients were estimated to be $243.000 or $40.500 per patient.14

Single use. New possibilities.

Outbreaks have led physicians to question the safety of bronchoscopy. Endoscopes, including bronchoscopes, are the medical devices most frequently associated with outbreaks of nosocomial infections.15, 16

The risk of cross-infection with multi-resistant microbes in the ICU during bedside bronchoscopy procedures can be significantly reduced by using a sterile single-use bronchoscope.

Ambu’s single-use aScope 4 Broncho minimizes the risk of cross-contamination by ensuring sterility straight from the pack, thus avoiding residual biofilm caused by inadequate automatic endoscope reprocessing.

Learn more

Want to know more?

Do you want to now more? Fill in your contact information in the form and we will contact you.

 

References

  1. CDC Guideline 2008. Disinfection and Sterilization in Healthcare Facilities.

  2. US senate report January 13, 2016 Preventable Tragedies: Superbugs and How Ineffective Monitoring of Medical Device Safety Fails Patients

  3. ECRI Institute https://www.ecri.org/Pages/default.aspx

  4. FDA News Release. FDA releases final guidance on reprocessing of reusable medical devices. March 12, 2015.

  5. Reprocessing Medical Devices in Health Care Settings: Validation Methods and Labeling. Guidance for Industry and Food and Drug Administration Staff. FDA. March 17, 2015.

  6. Go to article: Infections Associated with Reprocessed Flexible Bronchoscopes: FDA Safety Communication

  7. Go to: FDA MAUDE database

  8. Kovaleva et al. 2013; Transmission of Infection by Flexible Gastrointestinal Endoscopy and Bronchoscopy. Clinical Microbiology Rev. April 2013 vol. 26 no. 2, p. 231-254

  9. MM. Mughal et al.2004; Reprocessing the Bronchoscope: The Challenges, Seminars in Respiratory and Critical Care Medicine. Vol. 25 no. 4, p. 443-449

  10. Pajkos et al. Is biofilm accumulation on endoscope tubing a contributor to the failure of cleaning and decontamination? Journal of Hospital Infection 2004, 58:224-229.

  11. Terjesen et al. 2017; Early Assessment of the Likely Cost Effectiveness of Single-Use Flexible Video Bronchoscopes

  12. Michelle Alfa Ph.D.; Endoscope Reprocessing Verification Testing, Presentation, Meeting Materials Non-FDA Generated, FDA Committee Meeting, May 14-15, 2015

  13. R. Douglas Scott II, The Direct Medical Costs of Healthcare-Associated Infections in U.S. Hospitals and the Benefits of Prevention, Division of Healthcare Quality Promotion, National Center for Preparedness, Detection, and Control of Infectious Diseases, Centers for Disease Control and Prevention, March 2009

  14. Kovaleva et al. Usefulness of Bacteriological Monitoring of Endoscope Reprocessing, Therapeutic Gastrointestinal Endoscopy, Chap. 9, p. 141-162, 2011

  15. Srinivasan et al. An Outbreak of Pseudomonas aeruginosa Infections Associated with Flexible Bronchoscopes. The New England Journal of Medicine, 2003; 348;221-7

  16. CDC release from the Healthcare Infection Control Practices Advisory Committee (HICPAC) January 25, 2017. "Essential Elements of a Reprocessing Program for Flexible Endoscopes – Recommendations of the HICPAC

 